PRODUCTS

Flow Sensors / Vortex Akış Sensörü Tip 200

Vortex Akış Sensörü Tip 200

  • Description
  • Generic Details
  • Video
  • PDF

The flow sensors of Type 200 are based on the principle of the Kármán vortex street. The vortex flow sensors are free of moving parts, making them resistant to contamination. They are also characterized by a low pressure drop and high measurement accuracy. Optional variants with an integrated temperature sensor are available.

 

  • Low-cost product with very good accuracy

  • Temperature-insensitive measuring principle

  • Excellent media resistance (measuring element without media contact)

  • Wider operating temperature range

  • Low pressure loss

  • Dirt-insensitive measuring element

  • Temperature measurement directly in the medium optionally with PT1000 or NTC

  • Drinking water approvals KTW, W270, ACS, WRAS

General Features

 

Flow measurement principle

Vortex flow rate

Measuring range flow rate Overview

0.5 ... 150 l/min

Nominal width

6; 8; 10; 15; 20; 25

Accuracy < 50 % measuring range end value Water

<1 %FS

 

Accuracy > 50 % measuring range end value Water

<2 % (Measured value)

Switch-on Delay

<100 ms (Immediate response time; can be used for tapping operation)

Response Time

>5 ms

Temperature measuring principle

PT1000; NTC10k

Temperature measuring range

-40 ... 125 °C

Sensor Weight

44; 46; 57; 68; 92; 100 g

Repeatability

±0.5%

Sensor Type

Flow sensor, optionally with temperature measurement

Measuring range flow rate

0,5 ... 150 l/min

 

Temperature Measurement

 

Accuracy ΔT referred to 0 °C

±0,3K ± 0,005 · ΔT (Class B DIN EN 60751)

Accuracy @ T < 25 ºC

±0.7 °C ± 0.025 ΔT25 °C (NTC 10 kΩ @ 25 ºC)

Accuracy @ T > 25 ºC

±0.7 °C ± 0.025 ΔT25 °C (β = 4050)

Influence Self-heating temperature sensor

1 K/mW

Influence Conduction resistance to connector

0,8 Ohm

 

Field of application

 

Media

 

Heating water with standard additives; Drinking water; Other media on request

Medium temperature

-15 ... 125 °C (Non-freezing media)

Maximum test pressure at 40 °C media temperature

18 bar

Cavitation

>5,5 (Equation for avoiding cavitation: P abs outlet / P difference)

Maximum system pressure media temperature up to

90 °C

7 bar

Maximum pressure impact resistance at 90 °C media temperature

On request

Recommended minimum system pressure

1 bar

 

Material

 

Sensor paddle with media contact

ETFE

Housing with media contact

PA6T/6I (40 % glass fibre)

Sealing material with media contact

FKM; EPDM (perox.)

 

Electrical Data

 

Supply Voltage

5 VDC (±5%)

Output flow rate

Frequency square wave signal (< 0.1 ... > 4.75 V @ UIN = 5 VDC; Q; UOUT_Q_Frequency)

Temperature Output

PT1000 (PT1000 Class B DIN EN 60751); NTC10k (NTC 10 kΩ @ 25 ºC; β = 4050)

Electrical Connection

RAST 2.5 connector; Connector RAST 2.54; M12x1 connector

IP protection class

IP 20; IP 65

Load/burden

> 10 kΩ / < 10 nF (against GND or IN)

Current consumption

<6 mA (Standard); <10 mA (increased noise immunity)

 

Approval

 

EMC compatibility

according to EN 61326-2-3 (without protection against surge)

Drinking water

Plastic parts with KTW and W270 approval; WRAS; ACS

Name product : Vortex Akış Sensörü Tip 200